Line 23: Line 23:
 
|Drill down until you find the drawing you would like to use and Click '''[open]''' button || The drawing will be located in the save folder you specified for that project. ''Example'' '''..\MyDocuments\Project1\EquipmentRoom13\FileA.dwg'''
 
|Drill down until you find the drawing you would like to use and Click '''[open]''' button || The drawing will be located in the save folder you specified for that project. ''Example'' '''..\MyDocuments\Project1\EquipmentRoom13\FileA.dwg'''
 
|-
 
|-
|At this point you will be asked if you would like to ''Copy before opening'' [[File:Wiki_Snipit.png‎ ]] || If you are simply using the drawing for reference ''(Not changing or adding to project)'' you can Click ''[No ]''.  '''If you plan to add or make any changes to the drawing you will want to Click [Yes ]'''
+
|At this point you will be asked if you would like to ''Copy before opening'' [[File:Wiki_Snipit.png‎ ]] || If you are simply using the drawing for reference ''(Not changing or adding to project)'' you can Click ''[No ]''.  '''If you plan to add or make any changes to the drawing you will want to Click [Yes ]''' [[File:Wiki Snipit 1]]
 
|-
 
|-
 
|Your drawing will now be avaliable for edit however none of its data ''(Sysnames, Cable numbers Etc.)'' will be in the project database. ||Cable numbers cannot be reused however if it is possible to use the existing Sysnames, ''Click'' '''Advanced Tools>Equipment Functions>Slurp Sysnames'''. This will take a few moments and pull all Sysname data from the drawing and add it to the Project Database. To verify there are no errors with existing data, ''Click'' '''Advanced Tools>Equipment Functions>Drawing Sysname Error Check'''
 
|Your drawing will now be avaliable for edit however none of its data ''(Sysnames, Cable numbers Etc.)'' will be in the project database. ||Cable numbers cannot be reused however if it is possible to use the existing Sysnames, ''Click'' '''Advanced Tools>Equipment Functions>Slurp Sysnames'''. This will take a few moments and pull all Sysname data from the drawing and add it to the Project Database. To verify there are no errors with existing data, ''Click'' '''Advanced Tools>Equipment Functions>Drawing Sysname Error Check'''

Revision as of 18:21, 5 October 2011

Command Line Shortcut: '

User Permissions Level: All
Product Level: All
This will allow you to use a drawing from an existing project in a new or current project.




Before You Start

  1. You will need to know where your existing drawing is located on your machine (where that project and drawings were saved)
  2. Are you going to use the Sysnames from the existing drawing or are you going to create new Sysnames. (In some occasions Sysnames will not be able to be reused. Cable numbers will not be reusable in your current project).


How To Use An Existing Drawing In A Current Project

Step Description
With your current project open, Click File>Open Drawing or enter o into the Command Line
Drill down until you find the drawing you would like to use and Click [open] button The drawing will be located in the save folder you specified for that project. Example ..\MyDocuments\Project1\EquipmentRoom13\FileA.dwg
At this point you will be asked if you would like to Copy before opening Wiki Snipit.png If you are simply using the drawing for reference (Not changing or adding to project) you can Click [No ]. If you plan to add or make any changes to the drawing you will want to Click [Yes ] File:Wiki Snipit 1
Your drawing will now be avaliable for edit however none of its data (Sysnames, Cable numbers Etc.) will be in the project database. Cable numbers cannot be reused however if it is possible to use the existing Sysnames, Click Advanced Tools>Equipment Functions>Slurp Sysnames. This will take a few moments and pull all Sysname data from the drawing and add it to the Project Database. To verify there are no errors with existing data, Click Advanced Tools>Equipment Functions>Drawing Sysname Error Check
To clear all cable number data, Click Advanced Tools>Cable Functions>Reset All Cable Numbers In Drawings This will reset all cable numbers in the drawing and allow you to assign new numbers. This does not update data automatically to your Project Database. You will need to manuallly save after you have made your changes.
To clear all Sysname data, Click Advanced Tools>Equipment Functions>Reset All Sysnames In Drawing This will reset all Sysnames in the drawing and allow you to create new Sysnames. This doesn not update data automatically to your Project Database. You will need to manually save after you have made your changes.


ScreenShots

Before Reseting Data

Before.png

This image shows you a drawing with existing Sysnames and cable numbers.





After Reseting Data

After.png

This image shows you the same drawing as above only after using the "Reset All Cable Numbers In Drawings" and "Reset All Sysnames In Drawings" commands






Before Slurping Sysnames

Before Slurp.png

This image shows your Systems Database before using the "Slurp Sysname" command.






After Slurping Sysnames

After Slurp.png

This image shows your Systems Database after using the "Slurp Sysname" command







Saving Updated Drawing Data

You will need to manually save your drawing after any of the following:

Reseting all cable numbers in drawing.
Reseting all Sysname data in drawing.

Your drawing is now ready to be customised to fit your current project. After updating Sysnames and Cable Numbers, all data will be availiable in your reports.