Knowledge Base

Knowledge Base
Subject: Orphaned equipment all of a sudden
Status Resolved
Product WireCAD v9
Product Level PRO
Database Type VISTADB
Build Number (last 4 digits of version) 17021

Message

Customer
I've been working on a project, but all of a sudden I have equipment that's orphaned. I see it in the database, but they're all highlighted in pink.
05-May-2017 (04:41 PM)
The pink records in the Equipment List could be any one of the follow reasons:
Orphaned Manufacturer- Manufacturer Name is missing from the Global Equipment Database (GEDB).
Orphaned Equipment Name - Equipment Name field is missing from the GEDB.
The SysName has be deleted (marked Available = true).
The Manufacturer Name is duplicated.
The Equipment Name is duplicated.
07-May-2017 (10:07 PM)
Support
Customer
How would that have happened? I did not remove a manufacturer name, or equipment name, nor did I mark SysName to be deleted... I don't see any duplicate manufacturer names or equipment...
08-May-2017 (10:49 AM)
If they are not deleted this usually happens if a SQL server cannot be reached and fails back to the local GEDB. The duplicates can occur due to a sync with an outbound database.
08-May-2017 (09:40 PM)
Support
Customer
Sorry to be a pest, but what happens if we're not using a SQL server and it's only the local DB?
11-May-2017 (11:28 AM)
Have you done a database synchronize with another global database where the items were deleted from the other database?
16-May-2017 (04:12 PM)
Support
Customer
No, everything has been local files.
18-May-2017 (07:52 PM)
The global databases needed to be synced between WireCAD v8 and v9 upgrade.
20-May-2017 (01:16 PM)
Support