'Release notes WireCAD v2.0.1223 hot fix
'(c) 2000-2003 Holbrook Enterprises, Inc.
'****************************************
Cumulative fixes to 2.0.1096 release version.


To Install:
1. Run setup.exe


*****************************************
Updates and fixes:

1. Added getting started dialog. Note: the Project Drawings tab of the getting started dialog has a right-click context menu that allows viewing as list or icons and unlocking drawings.

2. Fixed "Others" selection box in equipment library not filling with signal types.

3. Fixed tab order in equipment library I/O editor.

4. Fixed unhandled error 75 error when creating a new project and selecting a file instead of a path.

5. Fixed - double clicking on a dwg file without a previous reference in the drawings database would not display the file.

6. Added Help>Upgrade WireCAD menu to allow access to authorization code.

7. Fixed - drawing opened from the Open Drawing dialog would not display an icon in the Project Explorer.

8. Enabled Consolidate and Move function.

9. Modified error handling to allow orderly shut down.

10. Fixed - error 13 when canceling export to bmp.

11. Fixed - error with CTL-Z undo. No longer have to press the undo button multiple times to undo.

12. Changed menu description from Equipment>Add to Equipment>Equipment Library...

13. Added View Data Sheet function to cable types library to enable editing of the table.

14. Added MouseWheel Property to the Drawing Properties window. This allows the mousewheel action to be reversed from its normal action.

15. Fixed - DA blocks inserted from the dropdown do not behave as DA blocks.

16. Fixed - Looped inputs did not assign properly.

17. Fixed - Field list and context menus not displaying properly in report designer.

18. Fixed - Overflow error when adding long cable numbers.

19. Fixed - Signal Types table would not enter edit mode if the color button alone was clicked. Color would change but not be updated unless number was manually entered.

20. Fixed - problem updating attribute properties.

21. Fixed - problem on some systems printing global grids. Grids would not print more than one page.

22. Modified - the Zoom Scale form to work with viewports only. 

23. Fixed - CTL-C CTL-X copy to clipboard cut to clipboard error with selection set.

24. Exposed DimText property.

25. Fixed - linked pointers assignment problem. 

26. Fixed - array function leaves gips shown

27. Added [DrawingName*] form caption to indicate modified drawing

28. Modified consolidate and link functions to synchronize equipment database.

29. Fixed - Entities left highlighted after some functions could not be unhighlighted by hitting escape unless re-selected.

30. Fixed - Error 13 when trying to assign an orphaned block or cable.

31. Fixed - Cable assignments bypassing the verify setting dialog do not use the cable type defined in the signal types database.

32. Fixed - linked pointers of mismatched signal types did not create the appropriate layers and would not display correctly.

33. Fixed - firstcharacter typed into command line from ten key pad would send the wrong character.

34. Included in this hotfix are several different templates dispaying different jack styles. Take a look and see if any of them strike your fancy.

35. Fixed - Problem when using undo after deleting a selection set with more than one entity. Crashed to OS

36. Added System Validator which runs on application startup. If no discrepencies are found it does nothing otherwise it tells you what needs to be changed on your system. Also available from Help>System Validator.

37. Added Database Conflict Resolver. To access this function. Close all drawings and databases and click on Databases>Conflict Resolver. Conflicts arrise in replicated databases when records are deleted from one database but not the other, or if WireCAD is unable to enforce referencial integrity. The resolver allows you to chose which records are kept and which are discarded.

38. Modified BOM so that report displays the selected filename from the generate BOM function.

39. Modified cable number to accept alpha characters to the right of a dash (-).

40. Many other minor bug fixes!